  "id": "home-charging-circuits",
  "title": "Home charging by circuit",
  "description": "What each common home circuit can deliver to an electric car: charger amps, power, and miles of range per hour.",
  "publisher": {
    "name": "Fox River Press",
    "url": "https://foxriverpress.com/"
  },
  "site": "https://chargeathome.info/",
  "page": "https://chargeathome.info/",
  "license": {
    "id": "CC-BY-4.0",
    "name": "CC BY 4.0",
    "url": "https://creativecommons.org/licenses/by/4.0/"
  },
  "cite": "Fox River Press (2026). Home charging by circuit (version 1.0.0) [Data set]. https://foxriverpress.com/datasets/home-charging-circuits",
  "version": "1.0.0",
  "released": "2026-11-16",
  "updated": "2026-11-16",
  "checked": "2026-10-23",
  "sha256": "676644a3f998c1ed10ff87f28a42575d9d71115db5a060dd0c2b030a556f87fd",
  "method": "Computed, not measured. Charger amps are 80 percent of the breaker (the continuous-load rule), power is volts times amps, and miles per hour apply the stated efficiency and loss. The same functions run the calculator on the site, and a test holds every number a guide prints to them. Change an assumption and the miles change; the amps and kilowatts do not.",
  "files": {
    "page": "https://foxriverpress.com/datasets/home-charging-circuits",
    "json": "https://foxriverpress.com/datasets/home-charging-circuits/home-charging-circuits.json",
    "csv": "https://foxriverpress.com/datasets/home-charging-circuits/home-charging-circuits.csv",
    "changes": "https://foxriverpress.com/datasets/home-charging-circuits/changes.xml"
  },
  "columns": [
    {
      "key": "id",
      "label": "Id",
      "type": "string"
    },
    {
      "key": "setup",
      "label": "Setup",
      "type": "string"
    },
    {
      "key": "volts",
      "label": "Volts",
      "type": "number"
    },
    {
      "key": "breaker_amps",
      "label": "Breaker (A)",
      "type": "number"
    },
    {
      "key": "charger_amps",
      "label": "Charger setting (A)",
      "type": "number",
      "note": "80 percent of the breaker"
    },
    {
      "key": "kw",
      "label": "Power (kW)",
      "type": "number"
    },
    {
      "key": "miles_per_hour",
      "label": "Miles of range per hour",
      "type": "number",
      "note": "At the assumptions below"
    },
    {
      "key": "miles_in_10_hours",
      "label": "Miles in 10 hours",
      "type": "number"
    }
  ],
  "assumptions": [
    {
      "label": "Continuous-load share",
      "value": 0.8,
      "note": "A charger may draw 80 percent of its breaker (NEC Article 625)"
    },
    {
      "label": "Efficiency (kWh per 100 miles)",
      "value": 30,
      "note": "example; your car's figure is on its fueleconomy.gov label"
    },
    {
      "label": "Charging loss share",
      "value": 0.12,
      "note": "assumption: energy lost as heat between the meter and the battery"
    },
    {
      "label": "Electricity price (cents per kWh)",
      "value": 18.2,
      "note": "U.S. residential average, 2026 (EIA projection)"
    }
  ],
  "sources": [
    {
      "label": "NFPA 70, National Electrical Code (Article 625 covers EV charging equipment)",
      "url": "https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70"
    },
    {
      "label": "U.S. DOE and EPA, fueleconomy.gov: compare electric vehicles",
      "url": "https://www.fueleconomy.gov/feg/evsbs.shtml"
    },
    {
      "label": "U.S. EIA Short-Term Energy Outlook, October 2026: Electricity",
      "url": "https://www.eia.gov/outlooks/steo/report/elec_coal_renew.php"
    },
    {
      "label": "U.S. DOE Alternative Fuels Data Center: Charging Plug-In Electric Vehicles at Home",
      "url": "https://afdc.energy.gov/fuels/electricity-charging-home"
    }
  ],
  "changes": [
    {
      "date": "2026-11-16",
      "version": "1.0.0",
      "what": "First release."
    }
  ],
  "rows": [
    {
      "id": "l1-12",
      "setup": "Level 1, 120 V outlet",
      "volts": 120,
      "breaker_amps": 15,
      "charger_amps": 12,
      "kw": 1.44,
      "miles_per_hour": 4.2,
      "miles_in_10_hours": 42
    },
    {
      "id": "l1-16",
      "setup": "Level 1, 120 V, 20 A circuit",
      "volts": 120,
      "breaker_amps": 20,
      "charger_amps": 16,
      "kw": 1.92,
      "miles_per_hour": 5.6,
      "miles_in_10_hours": 56
    },
    {
      "id": "l2-16",
      "setup": "Level 2, 240 V, 20 A circuit",
      "volts": 240,
      "breaker_amps": 20,
      "charger_amps": 16,
      "kw": 3.84,
      "miles_per_hour": 11.3,
      "miles_in_10_hours": 113
    },
    {
      "id": "l2-24",
      "setup": "Level 2, 240 V, 30 A circuit",
      "volts": 240,
      "breaker_amps": 30,
      "charger_amps": 24,
      "kw": 5.76,
      "miles_per_hour": 16.9,
      "miles_in_10_hours": 169
    },
    {
      "id": "l2-32",
      "setup": "Level 2, 240 V, 40 A circuit",
      "volts": 240,
      "breaker_amps": 40,
      "charger_amps": 32,
      "kw": 7.68,
      "miles_per_hour": 22.5,
      "miles_in_10_hours": 225
    },
    {
      "id": "l2-40",
      "setup": "Level 2, 240 V, 50 A circuit",
      "volts": 240,
      "breaker_amps": 50,
      "charger_amps": 40,
      "kw": 9.6,
      "miles_per_hour": 28.2,
      "miles_in_10_hours": 282
    },
    {
      "id": "l2-48",
      "setup": "Level 2, 240 V, 60 A circuit",
      "volts": 240,
      "breaker_amps": 60,
      "charger_amps": 48,
      "kw": 11.52,
      "miles_per_hour": 33.8,
      "miles_in_10_hours": 338
    }
  ]
}